code change · fixManufacturingofficial - Microsoftreviewed - checked by Opus

#12059 [Master]-Reverse Production Entry fails when production output is posted using a non-base Unit of Measure.

Reversing a production entry no longer fails when the production output was posted using a non-base unit of measure. The fix is in the Undo Prod. Posting Mgmt. codeunit.

Pull request · merged into main (BC30) on 2026-10-05 by neeleshsinghal · 2 files (+65 -2), 1 AL · fix · tier official · reviewed (checked by Opus)

What changed

  • Reversing production output posted with a non-base unit of measure previously failed
  • Fix applied in codeunit Undo Prod. Posting Mgmt.
  • New test added in SCM Production Orders II
  • Behaviour changes for users or extensions.

AL objects touched

Context

  • Work items: AB#652999
  • Labels: Team: SCM
  • Systems: manufacturing