#13428 [Quality Management] Keep Sample Size and Pass/Fail Quantity within Quantity (Base)
Quality Management inspections now enforce that Sample Size and Pass/Fail Quantity cannot exceed Quantity (Base), preventing data inconsistencies when Quantity (Base) is reduced after inspection creation or when it is zero.
- 4files
- 2AL files
- 2objects
Pull request · merged into main (BC30) on 2026-11-06 by alexei-dobriansky · 4 files (+106 -6), 2 AL · fix · tier official · reviewed (checked by Opus)
What changed
- Sample Size and template Sample Fixed Amount now have MinValue = 0; a negative fixed amount already on a template is treated as 0 so posting is not blocked
- Validating Quantity (Base) re-caps a Sample Size that exceeds it
- On Finish the applied quantity is Sample Size if above 0, otherwise Quantity (Base), always capped at Quantity (Base), with no silent early exit
- Inspections with Quantity (Base) = 0 now finish with Pass/Fail 0 instead of the sample size
- Pass/Fail Quantity tooltips state the cap; existing negative Sample Size values are not migrated
- Behaviour changes for users or extensions.
AL objects touched
- Table 20402 “Qlty. Inspection Template Hdr.”, Quality Management: modified
- Table 20405 “Qlty. Inspection Header”, Quality Management: modified
Also merged into
- #13797 into
releases/29.xon 2026-11-12
Context
- Work items: AB#655845, AB#655846
- Labels: AL: Apps (W1), Team: SCM
- Systems: inventory