BCQuality rule · performanceAL Developmentofficial - Microsoftderived - from the source, no model text

Set DataAccessIntent ReadOnly on analytical objects

DataAccessIntent was introduced at runtime 5.0 (BC 16) and has no effect in earlier versions. Reports, API pages (PageType = API with Editable = false), and queries that only read can run against a read replica when DataAccessIntent = ReadOnly.

Rule on GitHub · microsoft layer · performance · BC 16.. · tier official · derived

Contributions welcome — open a PR to refine or extend this article.

Description

DataAccessIntent was introduced at runtime 5.0 (BC 16) and has no effect in earlier versions. Reports, API pages (PageType = API with Editable = false), and queries that only read can run against a read replica when DataAccessIntent = ReadOnly. For queries, replica routing only applies when the query is exposed via OData/API; running a query in AL code is unaffected. Without the property these objects hit the primary replica and compete with posting. Agents omit it because the default is read-write and the object “only reads” in AL. The replica routing is a metadata switch, not something the compiler infers from the absence of Modify.

Best Practice

On report objects and PageType = API pages with Editable = false that never write, set DataAccessIntent = ReadOnly. For query objects, set it when the query is consumed via OData or an API endpoint. Keep the default on objects that insert, modify, or call a write codeunit from a processing-only report.

See sample: dataaccessintent-readonly-on-analytical-objects.good.al.

Anti Pattern

A listing report or API query with no DataAccessIntent that scans G/L or sales lines. The object is read-only in practice and still loads the primary.

See sample: dataaccessintent-readonly-on-analytical-objects.bad.al.

Examples

Changed by


From microsoft/BCQuality at aaaf6c1, MIT License, Copyright (c) 2026 Microsoft Corporation (license).