Clear a Report variable before an independent RunModal execution

Report.Run() automatically clears the report variable after execution, but Report.RunModal() does not. Reconfiguring and running the same variable for an independent operation can therefore retain filters and other instance state from the previous run.

Rule on GitHub · microsoft layer · reporting · BC all · tier official · derived

Description

Report.Run() automatically clears the report variable after execution, but Report.RunModal() does not. Reconfiguring and running the same variable for an independent operation can therefore retain filters and other instance state from the previous run.

Best Practice

Call Clear(ReportVariable) before configuring a new, logically independent RunModal() execution on a reused report variable. No clear is required after a single execution, and retaining state is valid when the subsequent run intentionally continues with the same configuration.

See sample: clear-report-variable-before-independent-runmodal.good.al.

Anti Pattern

Run the same report variable modally for two independent views without clearing it between runs. The second SetTableView can only narrow the existing report view, so filters retained by the instance can make the second result incomplete or empty.

See sample: clear-report-variable-before-independent-runmodal.bad.al.

References

Report.RunModal() method — https://learn.microsoft.com/dynamics365/business-central/dev-itpro/developer/methods-auto/report/reportinstance-runmodal-method

Report.Run() method — https://learn.microsoft.com/dynamics365/business-central/dev-itpro/developer/methods-auto/report/reportinstance-run-method

Examples

Changed by


From microsoft/BCQuality at a4593a1, MIT License, Copyright (c) 2026 Microsoft Corporation (license).