Codeunit 1367 "Monitor Sensitive Field Data"
Base Application · System.Diagnostics
Across versions
- BC23-26present
- BC271 procedures added, 1 procedures removed
- BC28-30unchanged
Neighbourhood 5 connected objects and pages
Base Application · System.Diagnostics · BC23-30 · source at ea08af5e · facts from BC29
Properties
| Property | Value |
|---|---|
| Permissions | tabledata “Field Monitoring Setup” = im |
Event subscriptions
- OnAfterInsertMonitoredField subscribes to Table “Change Log Setup (Field)” OnAfterInsertEvent
- OnAfterDeleteMonitoredField subscribes to Table “Change Log Setup (Field)” OnAfterDeleteEvent
Procedures
CheckIfTableIsMonitored(var TempChangeLogSetupTable: Record "Change Log Setup (Table)" temporary; FieldMonitoringSetup: Record "Field Monitoring Setup"; ChangeLogSetup: Record "Change Log Setup"): BooleanHandleMonitorSensitiveFields(var ChangeLogEntry: Record "Change Log Entry"; var TempChangeLogSetupField: Record "Change Log Setup (Field)" temporary; RecRef: RecordRef; FldRef: FieldRef; IsAlwaysLoggedTable: Boolean; IsMonitorEnabled: Boolean)IsIgnoredMonitorField(Recref: RecordRef; FldRef: FieldRef): BooleanOpenChangedRecordPage(TableNo: Integer; FieldNo: Integer; RecordSystemID: Guid)ResetNotificationCount()
Plus 2 local procedures.
Calls
From the extracted call graph of BC29 (graphify-al on the snapshot checkout): calls whose target is known from a declared type or an Object::"Name" argument. Interface dispatch and calls through events are not counted, so the list is not complete.
- Codeunit 1368 “Monitored Field Notification” (2 calls:
HandleMonitorSensitiveFields → SendEmailNotificationOfSensitiveFieldChange,IsAlwaysLoggedMonitorTable → SendEmailNotificationOfSensitiveFieldChange) - Codeunit 1392 “Monitor Sensitive Field” (1 call:
IsMonitoredField → IsValidTable) - Codeunit 700 “Page Management” (1 call:
OpenChangedRecordPage → PageRunAtField)
Called by
- Codeunit 423 “Change Log Management” (4 calls:
GetDatabaseTableTriggerSetup → CheckIfTableIsMonitored,InsertLogEntry → HandleMonitorSensitiveFields,InsertLogEntry → IsIgnoredMonitorField, …) - Page 1367 “Monitored Field Log Entries” (1 call:
OnOpenPage → ResetNotificationCount)
Ask your agent
Procedure bodies are not stored here (D10). The call sections above are our own, per object, from the BC29 call graph. For a procedure body or the calls of one procedure, ask bc-code-atlas (external, by Stefan Maron, MIT; default corpus w1-28), which the bc-observatory plugin connects: bcatlas_resolve_node(object_type: "codeunit", object_name: "Monitor Sensitive Field Data"), then bcatlas_get_procedure_body or bcatlas_get_neighbors on the returned id.