Page 1179 "Job Queue Notification Wizard"
Base Application · Microsoft.System.Threading
Across versions
- BC23-24not present
- BC25added
- BC26-30unchanged
Neighbourhood 4 connected objects and pages
Base Application · Microsoft.System.Threading · captioned “Set Up Job Queue Notifications” · BC25-30 · source at ea08af5e · facts from BC29
Properties
| Property | Value |
|---|---|
| Caption | Set Up Job Queue Notifications |
| Extensible | false |
| SourceTable | Job Queue Notification Setup |
| PageType | NavigatePage |
Fields on this page
Layout controls in source order, grouped by the container they sit in. Shows: the table field a control is bound to (or its expression as written); ToolTip: the control’s own, else the bound field’s (marked).
| Group | Control | Shows | ToolTip |
|---|---|---|---|
| Control17 | MediaResourcesStandardMediaReference | MediaResourcesStandard."Media Reference" |
— |
| Control19 | MediaResourcesDoneMediaReference | MediaResourcesDone."Media Reference" |
— |
| Para2.1.1 | Notify the user who initiates background tasks | NotifyUserInitiatingTask | Specifies whether the user who initiates a background task should receive a notification when the task is failed. |
| Notify these job queue notification administrators | NotifyAdmin |
Specifies whether these job queue notification administrators should receive a notification when any task is failed in Job Queue. | |
| Para2.1.2 | Job Queue Notification Administrators List | part Page 1182 “Job Queue Admin Setup” | — |
| How do you want to notify users? | In-product notifications | InProductNotification | Specifies if the notifications should be displayed in the Business Central web client. |
| Control notifications with business events (preview) | PowerAutomateFlowNotification | Specifies if the external business event will be enabled. | |
| When do you want to display in-product notifications? | Immediately for each job queue entry | NotifyWhenJobFailed | Specifies the user should receive a notification once the task is failed. |
| After a threshold is reached | NotifyAfterThreshold | Specifies the user should receive a notification when the count of failed jobs reach the low threshold. | |
| Low threshold | Threshold1 | Specifies the low threshold for the cue set up of failed jobs. | |
| High threshold | Threshold2 | Specifies the high threshold for the cue set up of failed jobs. | |
| To enable notifications using Power Automate: | CreateFlowFromTemplateTip | CreateFlowFromTemplateTipLbl |
— |
| CreateFlowFromTemplate | CreateFlowFromTemplateLbl |
— | |
| Step5 | Choose Finish to apply the setup and complete the guide. | label | — |
Actions
| Group | Action | ToolTip | Runs |
|---|---|---|---|
| Processing | Back | — | |
| Next | — | ||
| Finish | — |
Procedures
6 local procedures, no public ones.
Triggers
OnInit, OnOpenPage
Relations
- source table Table 9066 “Job Queue Notification Setup”
Calls
From the extracted call graph of BC29 (graphify-al on the snapshot checkout): calls whose target is known from a declared type or an Object::"Name" argument. Interface dispatch and calls through events are not counted, so the list is not complete.
- Codeunit 4030 “Client Type Management” (1 call:
LoadTopBanners → GetCurrentClientType) - Codeunit 454 “Job Queue - Send Notification” (1 call:
UpdateMyNotificationSetup → GetJobQueueFailedNotificationId) - Codeunit 8703 “Feature Telemetry” (1 call:
OnOpenPage → LogUptake)
Ask your agent
Procedure bodies are not stored here (D10). The call sections above are our own, per object, from the BC29 call graph. For a procedure body or the calls of one procedure, ask bc-code-atlas (external, by Stefan Maron, MIT; default corpus w1-28), which the bc-observatory plugin connects: bcatlas_resolve_node(object_type: "page", object_name: "Job Queue Notification Wizard"), then bcatlas_get_procedure_body or bcatlas_get_neighbors on the returned id.