Page 9701 "Cue Setup Administrator"
System Application · System.Visualization
Across versions
- BC23-30present
Neighbourhood 3 connected objects and pages
System Application · System.Visualization · captioned “Cue Setup” · BC23-30 · source at ea08af5e · facts from BC29
Properties
| Property | Value |
|---|---|
| Caption | Cue Setup |
| SourceTable | Cue Setup |
| PageType | List |
| UsageCategory | Administration |
| ApplicationArea | All |
| Permissions | tabledata “Cue Setup” = rimd |
Fields on this page
Layout controls in source order, grouped by the container they sit in. Shows: the table field a control is bound to (or its expression as written); ToolTip: the control’s own, else the bound field’s (marked).
| Group | Control | Shows | ToolTip |
|---|---|---|---|
| Group | User Name | User Name | Specifies which Business Central user the indicator setup for the Cue pertains to. If you leave this field blank, then the indicator setup will pertain to all users. |
| Table ID | Table ID | Specifies the ID of the Business Central table that contains the Cue. | |
| Table Name | Table Name | Specifies the name of the table that contains the field that defines the Cue. | |
| Field No. | Field No. | Specifies the ID that is assigned the Cue. | |
| Field Name | Field Name | Specifies the name that is assigned to the Cue. | |
| Low Range Style | Low Range Style | Specifies the color of the indicator when the value of data in the Cue is less than the value that is specified by the Threshold 1 field. | |
| Threshold 1 | Threshold 1 | Specifies the value in the Cue below which the indicator has the color that is specified by the Low Range Style field. | |
| Middle Range Style | Middle Range Style | Specifies the color of the indicator when the value of data in the Cue is greater than or equal to the value that is specified by the Threshold 1 field but less than or equal to the value that is specified by the Threshold 2 field. | |
| Threshold 2 | Threshold 2 | Specifies the value in the Cue above which the indicator has the color that is specified by the High Range Style field. | |
| High Range Style | High Range Style | Specifies the color of the indicator when the value in the Cue is greater than the value of the Threshold 2 field. |
Procedures
1 local procedures, no public ones.
Triggers
OnAfterGetRecord, OnNewRecord
Relations
- source table Table 9701 “Cue Setup”
Calls
From the extracted call graph of BC29 (graphify-al on the snapshot checkout): calls whose target is known from a declared type or an Object::"Name" argument. Interface dispatch and calls through events are not counted, so the list is not complete.
- Codeunit 9702 “Cues And KPIs Impl.” (1 call:
UpdateThresholdStyles → ConvertStyleToStyleText)
Documented on Microsoft Learn
Source: AL metadata extracted from the code (names, ids, signatures, properties); no code bodies (D10).
Ask your agent
Procedure bodies are not stored here (D10). The call sections above are our own, per object, from the BC29 call graph. For a procedure body or the calls of one procedure, ask bc-code-atlas (external, by Stefan Maron, MIT; default corpus w1-28), which the bc-observatory plugin connects: bcatlas_resolve_node(object_type: "page", object_name: "Cue Setup Administrator"), then bcatlas_get_procedure_body or bcatlas_get_neighbors on the returned id.