Table 404 "Change Log Setup (Field)"
Base Application · System.Diagnostics
Across versions
- BC23present
- BC242 fields changed
- BC25-30unchanged
Neighbourhood 7 connected objects and pages
Base Application · System.Diagnostics · BC23-30 · source at ea08af5e · facts from BC29
Learn documents this table through its pages: Page 1369 “Monitored Fields Worksheet” (2 Learn pages).
Properties
| Property | Value |
|---|---|
| Caption | Change Log Setup (Field) |
| DataClassification | CustomerContent |
Fields
Explanation: the field’s ToolTip in the code; without one, the ToolTip of a page control bound to the field (marked via the page); without that, its Caption (marked caption) when that differs from the name.
| No. | Name | Type | Explanation | Notes |
|---|---|---|---|---|
| 1 | Table No. | Integer | — | TableRelation Table 403 “Change Log Setup (Table)” (Change Log Setup (Table)) |
| 2 | Field No. | Integer | Specifies the identifier of the monitored field. via Page 1369 “Monitored Fields Worksheet” | TableRelation Field.“No.” where(TableNo = field(“Table No.”)) |
| 3 | Field Caption Δ BC24 | Text[100] | Specifies the name of the monitored field. via Page 1369 “Monitored Fields Worksheet” | FlowField: lookup(Field.“Field Caption” where(TableNo = field(“Table No.”), “No.” = field(“Field No.”))) |
| 4 | Log Insertion | Boolean | — | |
| 5 | Log Modification | Boolean | — | |
| 6 | Log Deletion | Boolean | — | |
| 7 | Monitor Sensitive Field | Boolean | — | DataClassification SystemMetadata |
| 8 | Notify | Boolean | Specifies whether to send an email notification when the value in this monitored field is changed. The email is sent to the recipient specified on the Field Monitoring Setup page. via Page 1369 “Monitored Fields Worksheet” | DataClassification SystemMetadata |
| 9 | Table Caption Δ BC24 | Text[250] | Specifies the name of the table that includes the monitored field. via Page 1369 “Monitored Fields Worksheet” | FlowField: lookup(AllObjWithCaption.“Object Caption” where(“Object Type” = const(Table), “Object ID” = field(“Table No.”))) |
Keys
- Key1: Table No., Field No. (clustered)
Trigger event subscribers
- OnAfterDeleteEvent: Codeunit 1367 “Monitor Sensitive Field Data” OnAfterDeleteMonitoredField, Codeunit 423 “Change Log Management” OnAfterDeleteChangeLogSetupField
- OnAfterInsertEvent: Codeunit 1367 “Monitor Sensitive Field Data” OnAfterInsertMonitoredField, Codeunit 423 “Change Log Management” OnAfterInsertChangeLogSetupField
- OnAfterModifyEvent: Codeunit 423 “Change Log Management” OnAfterModifyChangeLogSetupField
- OnAfterRenameEvent: Codeunit 423 “Change Log Management” OnAfterRenameChangeLogSetupField
Triggers
OnDelete, OnRename
Relations
- Table No.: TableRelation Table 403 “Change Log Setup (Table)”
Pages and codeunits on this table
- Page 1369 “Monitored Fields Worksheet” (source table)
Calls
From the extracted call graph of BC29 (graphify-al on the snapshot checkout): calls whose target is known from a declared type or an Object::"Name" argument. Interface dispatch and calls through events are not counted, so the list is not complete.
- Codeunit 1392 “Monitor Sensitive Field” (3 calls:
OnDelete → DeleteChangeLogSetupTable,OnRename → DeleteChangeLogSetupTable,OnRename → InsertChangeLogSetupTable)
Ask your agent
Procedure bodies are not stored here (D10). The call sections above are our own, per object, from the BC29 call graph. For a procedure body or the calls of one procedure, ask bc-code-atlas (external, by Stefan Maron, MIT; default corpus w1-28), which the bc-observatory plugin connects: bcatlas_resolve_node(object_type: "table", object_name: "Change Log Setup (Field)"), then bcatlas_get_procedure_body or bcatlas_get_neighbors on the returned id.