Table 6217 "Sustainability Setup"
Sustainability · Microsoft.Sustainability.Setup
Across versions
- BC23-28not present
- BC29-30present
Neighbourhood 5 connected objects and pages
Sustainability · Microsoft.Sustainability.Setup · BC29-30 · source at ea08af5e · facts from BC29
Learn documents this table through its pages: Page 6221 “Sustainability Setup” (2 Learn pages).
Properties
| Property | Value |
|---|---|
| Caption | Sustainability Setup |
| DataClassification | CustomerContent |
Fields
Explanation: the field’s ToolTip in the code; without one, the ToolTip of a page control bound to the field (marked via the page); without that, its Caption (marked caption) when that differs from the name.
| No. | Name | Type | Explanation | Notes |
|---|---|---|---|---|
| 1 | Primary Key | Code[10] | — | |
| 2 | Emission Unit of Measure Code | Code[10] | Specifies the unit of measure code that is used to register emission. via Page 6221 “Sustainability Setup” | TableRelation Table 204 “Unit of Measure” (Unit of Measure) |
| 3 | Emission Reporting UOM Code | Code[10] | Specifies the unit of measure code that is used to report emission. via Page 6221 “Sustainability Setup” | TableRelation Table 204 “Unit of Measure” (Unit of Measure) |
| 4 | Reporting UOM Factor | Decimal | Specifies the unit of measure factor that is used to register emission. via Page 6221 “Sustainability Setup” | |
| 5 | Emission Decimal Places | Text[5] | Specifies the number of decimal places that are shown for emission amounts. The default setting, 2:5, specifies that all amounts are shown with a minimum of 2 decimal places and a maximum of 5 decimal places. You can also enter a fixed number, such as 2, which also means that amounts are shown with … via Page 6221 “Sustainability Setup” | |
| 6 | Emission Rounding Precision | Decimal | Specifies the size of the interval to be used when rounding emission amounts. via Page 6221 “Sustainability Setup” | NotBlank |
| 7 | Emission Rounding Type | Enum “Rounding Type” | Specifies how the program will round emission amount. via Page 6221 “Sustainability Setup” | enum Enum 9198 “Rounding Type” |
| 8 | Fuel/El. Decimal Places | Text[5] | Specifies the number of decimal places that are shown for fuel/electricity amounts. The default setting, 2:5, specifies that all amounts are shown with a minimum of 2 decimal places and a maximum of 5 decimal places. You can also enter a fixed number, such as 2, which also means that amounts are sho… via Page 6221 “Sustainability Setup” | |
| 9 | Distance Decimal Places | Text[5] | Specifies the number of decimal places that are shown for distance measurements. The default setting, 2:5, specifies that all amounts are shown with a minimum of 2 decimal places and a maximum of 5 decimal places. You can also enter a fixed number, such as 2, which also means that amounts are shown … via Page 6221 “Sustainability Setup” | |
| 10 | Custom Amt. Decimal Places | Text[5] | Specifies the number of decimal places that are shown for custom amounts. The default setting, 2:5, specifies that all amounts are shown with a minimum of 2 decimal places and a maximum of 5 decimal places. You can also enter a fixed number, such as 2, which also means that amounts are shown with tw… via Page 6221 “Sustainability Setup” | |
| 11 | CSRD Reporting Link | Text[250] | Specifies the Corporate Sustainability Reporting Directive link to report emission. via Page 6221 “Sustainability Setup” | |
| 12 | Country/Region Mandatory | Boolean | Specifies if country/region is mandatory. via Page 6221 “Sustainability Setup” | |
| 13 | Resp. Center Mandatory | Boolean | Specifies if responsibility center is mandatory. via Page 6221 “Sustainability Setup” | |
| 14 | Block Change If Entry Exists | Boolean | Specifies if the change of critical setup change is blocked when sustainability entry exists. via Page 6221 “Sustainability Setup” | |
| 15 | Enable Background Error Check | Boolean | Specifies if the background error check of sustainability journal lines is enabled. via Page 6221 “Sustainability Setup” | |
| 16 | Use Emissions In Purch. Doc. | Boolean | Specifies that you want to enable sustainability features in purchase documents. Until this field is selected, sustainability fields will not be displayed in the purchase lines. Select this field only if you intend to post your GHG emissions using purchase documents or to post purchasing carbon cred… via Page 6221 “Sustainability Setup” | |
| 17 | Waste Unit of Measure Code | Code[10] | Specifies the value of the Waste Unit of Measure Code field. via Page 6221 “Sustainability Setup” | TableRelation Table 204 “Unit of Measure” (Unit of Measure) |
| 18 | Water Unit of Measure Code | Code[10] | Specifies the value of the Water Unit of Measure Code field. via Page 6221 “Sustainability Setup” | TableRelation Table 204 “Unit of Measure” (Unit of Measure) |
| 19 | Disch. Into Water Unit of Meas | Code[10] | Specifies the value of the Discharged Into Water Unit of Measure Code field. via Page 6221 “Sustainability Setup” | TableRelation Table 204 “Unit of Measure” (Unit of Measure) |
| 20 | G/L Account Emissions | Boolean | Specifies the enablement of default Sustainability Account on the G/L Account card. via Page 6221 “Sustainability Setup” | |
| 21 | Item Emissions | Boolean | Specifies the enablement of default Sustainability Account emissions on the Item card. via Page 6221 “Sustainability Setup” | |
| 22 | Item Charge Emissions | Boolean | Specifies the enablement of default Sustainability Account emissions on the Item Charge. via Page 6221 “Sustainability Setup” | |
| 23 | Resource Emissions | Boolean | Specifies the enablement of default Sustainability Account emissions on the Resource card. via Page 6221 “Sustainability Setup” | |
| 24 | Work/Machine Center Emissions | Boolean | Specifies the enablement of default Sustainability Account emissions on the Work Center and Machine Center cards. via Page 6221 “Sustainability Setup” | |
| 25 | Enable Value Chain Tracking | Boolean | Specifies whether to generate sustainability value entries from procurement operations for Scope 3 upstream tracking. Enabling this automatically turns on: Use Emissions in Purchase Documents, Item Emissions, Resource Emissions, Fixed Asset Emissions, Item Charge and Work/Machine Center Emissions. E… via Page 6221 “Sustainability Setup” | |
| 26 | Energy Unit of Measure Code | Code[10] | Specifies the value of the Energy Unit of Measure Code field. via Page 6221 “Sustainability Setup” | TableRelation Table 204 “Unit of Measure” (Unit of Measure) |
| 27 | Energy Reporting UOM Code | Code[10] | Specifies the unit of measure code that is used to report Energy. via Page 6221 “Sustainability Setup” | TableRelation Table 204 “Unit of Measure” (Unit of Measure) |
| 28 | Energy Reporting UOM Factor | Decimal | Specifies the unit of measure factor that is used to register Energy. via Page 6221 “Sustainability Setup” | |
| 29 | Use All Gases As CO2e | Boolean | Specifies that you want to enable recording all gases as CO2 equivalent values. When this field is selected, the captions for gases will change from their names to their CO2e equivalents. The values you are expected to enter will correspond to their carbon equivalent values, not the original gas val… | |
| 30 | Posted ESG Reporting Nos. | Code[20] | Specifies the code for the number series that will be used to assign numbers to posted ESG Reporting nos. | TableRelation No. Series |
| 31 | Item Material Composition Nos. | Code[20] | Specifies the code for the number series that will be used to assign numbers to Item Material Composition Nos. | TableRelation No. Series |
| 32 | ESG Standard Reporting Nos. | Code[20] | Specifies the code for the number series that will be used to assign numbers for standard records created by dataverse to ESG Standard Reporting. | TableRelation No. Series |
| 40 | Is Dataverse Int. Enabled | Boolean | Specifies if the connection to Dynamics 365 Dataverse is enabled. via Page 6221 “Sustainability Setup” | DataClassification SystemMetadata |
| 41 | Use Formulas In Purch. Docs | Boolean | Specifies if the formula-based calculations are enabled for purchase documents. via Page 6221 “Sustainability Setup” | |
| 50 | Fixed Asset Emissions | Boolean | Specifies the enablement of default Sustainability Account emissions on the Fixed Asset card. via Page 6221 “Sustainability Setup” |
Keys
- Key1: Primary Key (clustered)
Procedures
GetRecordOnce()IsValueChainTrackingEnabled(): BooleanGetFormat(FieldNo: Integer): Text(internal)GetReportingParameters(var UOMCode: Code[10]; var UseUOMReportingFactor: Boolean; var UOMFactor: Decimal; var Direction: Text; var Precision: Decimal)(internal)IsDataverseIntegrationEnabled(): Boolean(internal)ExistSustainabilityLedgerEntryWithUnitOfMeasure(UnitOfMeasure: Code[10]): Boolean(internal)GetIntegrationTableIDFilter(): Text(internal)InitRecord()(internal)
Plus 5 local procedures.
Relations
- Disch. Into Water Unit of Meas: TableRelation Table 204 “Unit of Measure”
- Emission Reporting UOM Code: TableRelation Table 204 “Unit of Measure”
- Emission Unit of Measure Code: TableRelation Table 204 “Unit of Measure”
- Energy Reporting UOM Code: TableRelation Table 204 “Unit of Measure”
- Energy Unit of Measure Code: TableRelation Table 204 “Unit of Measure”
- Waste Unit of Measure Code: TableRelation Table 204 “Unit of Measure”
- Water Unit of Measure Code: TableRelation Table 204 “Unit of Measure”
Pages and codeunits on this table
- Page 6221 “Sustainability Setup” (source table)
Calls
From the extracted call graph of BC29 (graphify-al on the snapshot checkout): calls whose target is known from a declared type or an Object::"Name" argument. Interface dispatch and calls through events are not counted, so the list is not complete.
- Codeunit 8703 “Feature Telemetry” (2 calls:
InitRecord → LogUptake,InitRecord → LogUsage)
Recent changes
- 2026-07-29 #9613 [Master] - Sustainability: Specific Carbon Tracking, Item Charge emissions & setup fixes (Bugs 641051, 641486, 641487, 641049, 641222, 641055, 641289, 641224, 641309) (main, BC30, fix)
Ask your agent
Procedure bodies are not stored here (D10). The call sections above are our own, per object, from the BC29 call graph. For a procedure body or the calls of one procedure, ask bc-code-atlas (external, by Stefan Maron, MIT; default corpus w1-28), which the bc-observatory plugin connects: bcatlas_resolve_node(object_type: "table", object_name: "Sustainability Setup"), then bcatlas_get_procedure_body or bcatlas_get_neighbors on the returned id.